Solution
Air compressor industry
Transformation Scheme of Aodi AD300 Inverter Air Compressor
An air compressor is a device that uses an electric motor to compress gas in a compression chamber and make the compressed gas have a certain pressure. It has a wide range of uses and can be used in metallurgy, machinery manufacturing, mining, electric power, textile, petrochemical and other industries. Air compressors account for 15% of the power consumption of large industrial equipment (fans, pumps, boilers, air compressors, etc.).
After investigation, most of the air compressor itself has the following shortcomings:
(1) When the output pressure is greater than a certain value, the relief valve is automatically opened to make the asynchronous motor idling, which seriously wastes energy;
(2) The asynchronous motor is easy to start and stop frequently, which affects the service life of the motor;
(3) The degree of automation is low, and the adjustment of the output pressure is realized by the opening of the artificial control valve, the adjustment speed is slow, the fluctuation is large, the accuracy is low;
(4) The power frequency starting current of the air compressor is large, the impact on the power grid is large, the motor bearing wear is large, and the equipment maintenance is large.
Analysis of energy waste of traditional air compressor air supply system in 1.2:
There are two main working states of the traditional air compressor air supply system: one is the loading state and the other is the no-load state.
(1) Power consumption during loading
The loading state is that after the pressure reaches the minimum value, the original control mode determines that the pressure will continue to rise until the maximum pressure value. During the pressurization process, more heat must be released to the outside world, resulting in electrical energy loss. On the other hand, the pressure above the maximum value of the gas before entering the pneumatic components, the pressure needs to be reduced by the pressure reducing valve, which is also an energy-consuming process.
(2) Power consumption during unloading
In the no-load state, when the pressure reaches the maximum pressure, the air compressor reduces the pressure and unloads by the following methods: close the intake valve to make the motor in the idling state, and at the same time vent the excess compressed air in the separation tank through the vent valve. This adjustment method causes a great waste of energy. According to our calculation, the energy consumption of air compressor unloading accounts for about 10% ~ 25% of the full load operation of air compressor, which is still in the case of a small proportion of unloading time. In other words, the air compressor is idle for about 20% of the time and is doing useless work. Obviously, under the control mode of loading and unloading air supply, there is a lot of energy saving space for the air compressor motor.
The pressure control of the air supply system of the traditional air compressor is the upper and lower limit control. First, according to the minimum pressure requirement of the production equipment, the lower limit of the output pressure of the air compressor is set, that is, the pressure at which the air compressor starts to load. Then add about 1 Pa to the minimum pressure as the upper limit of the output pressure of the air compressor, that is, the pressure at which unloading starts. The output working pressure of the air compressor will fluctuate between the upper and lower limits. The power consumption of the air compressor is proportional to the output pressure. The higher the output pressure, the more power is consumed, and the 1 Pa pressure difference from the lower limit of the output pressure to the upper limit will consume 7-10% of the total power. In the traditional air supply air compressor system, if there are multiple air compressors running at the same time, the output pressure of each air compressor will fluctuate between the upper and lower limits with the pressure fluctuation of the pipe network, so each machine consumes more than 7-10% of the rated power.
The different setting of operating parameters in the traditional air compressor air supply system will also cause different power consumption of the air compressor. It must be set according to the gas consumption condition to achieve the most economical operation effect. Traditional air compressor air supply system because the motor is not allowed to start frequently, resulting in less air consumption when the motor is still no-load operation, a waste of electricity. Frequent unloading and loading causes the pressure of the entire gas network to change frequently and cannot maintain a constant working pressure.
the working principle of 2. air compressor:
The working principle diagram of the screw air compressor is shown in Figure 1. Air is sucked in through the air filter and the suction regulating valve. The regulating valve is mainly used to adjust the compression cavity formed by the cylinder, the rotor and the sliding vane. The rotor rotates in an eccentric manner relative to the cylinder. The sliding vane is installed in the groove of the rotor, and the sliding vane is pushed to the cylinder wall by centrifugal force. The efficient oil injection system can ensure good cooling of the compressor and the minimum comfortable consumption of lubricating oil. A thin layer is formed on the cylinder wall. The oil film can prevent direct contact between metal parts and cause wear. The temperature of the compressed air is relatively high, and a certain amount of oil and gas is mixed in it. After being separated by the oil and gas separator, the oil and gas are cooled by the oil cooler and then flow back to the oil storage tank through the oil filter. The air passes through the gas cooler (air cooling device). Cool and enter the gas storage tank.
3. air compressor transformation principle:
(1) The air outlet release valve is all closed, and the air supply adjustment method with the air outlet release valve is canceled to avoid the waste of electric energy caused thereby. Instead, the frequency converter adjusts the speed of the motor to adjust the gas flow, so that the power output of the motor is basically proportional to the flow demand, and the motor always works with high efficiency to achieve obvious power saving effect. For example, when the gas consumption is 50% of the rated gas supply, the power saving rate can reach more than 40%.
(2) The energy-saving mode of the frequency converter can make the motor run at the highest efficiency at light load and reduce unnecessary power loss;
(3) According to strict EMS standards, the high-efficiency PWM inverter uses high-speed and low-consumption IGBT to reduce harmonic distortion and motor power loss;
(4), can make the motor start, load when the current rise gently, without any impact; can make the motor to achieve soft stop, avoid the harm caused by the reverse current, is conducive to extending the service life of the equipment; avoid the current peak caused by the power company's fines;
(5) After the frequency conversion control system is adopted, the pressure of the gas in the gas supply pipeline can be monitored in real time, so that the pressure of the gas in the gas supply pipeline remains constant, and the production efficiency and product quality can be improved;
(6) Because the motor runs in a high-efficiency state, the power factor is high, which reduces reactive power loss and saves a lot of electric energy;
(7), save the original release valve system, when necessary, can participate in the adjustment, enhance the reliability of the system.
In short, the use of constant pressure gas supply intelligent control system, not only can save 30% to 40% of the electricity costs, prolong the service life of the compressor, and can achieve the purpose of constant pressure gas supply, improve production efficiency and product quality.
4. frequency conversion transformation scheme design principles:
4.1 the original gas supply system is introduced:
There are four 37kW air compressors in the polypropylene air supply system of a factory, which is the working flow chart of the original polypropylene air compressor air supply system. Three air compressors are used for power frequency power supply operation and the other air compressor is used as standby.
The existing problems are as follows: since the working air compressor is operated with power frequency power supply and is always operated at full load, the air pressure is low when catching up with the peak gas consumption; When the gas consumption is at a low ebb, especially during holidays, the air supply pressure is extremely large (the polypropylene gas supply system of the factory operates 24 hours a day). It is easy to damage the exhaust valve or the air pipe burst, while wasting electricity and reducing the service life of the equipment. Hope constant pressure air supply, three polypropylene air compressor balanced operation.
In view of the many problems existing in the air supply control mode of the screw air compressor system, we adopt frequency conversion speed regulation technology to control the constant pressure air supply of the two groups (I .e. 2 110kW) one-to-one air compressors in the factory. The energy-saving transformation of the gas supply system is carried out by using the AD300 frequency converter of Aodi.
Design scheme:
A pair of power frequency bypass is adopted, and the mode of use can be converted at the same time. The pipe network pressure of the polypropylene air compressor air supply system is taken as the control object, the pressure P of the air storage tank is collected by the pressure transmitter SP and converted into an electrical signal, which is sent to the PID self-tuning controller set in the frequency converter, compared with the pressure setting SV of the PID self-tuning controller, and calculated according to the difference value according to the established PID control mode to generate a control signal to control the working frequency and rotating speed of the motor through DSP, thus, the actual pressure P always approaches the set pressure value SV. The alarm function is preset. When the measured value exceeds the upper limit set value, AL1 sends an alarm signal, and when the measured value is lower than the lower limit set value, AL2 sends an alarm signal. Through the organic combination of frequency converter, pressure sensor and PID self-tuning controller, the closed-loop automatic control system of air supply is formed to automatically adjust the output pressure of air compressor. Make the utilization rate of each air compressor equal, increase the stability and reliability of the system and pipeline pressure, and facilitate technicians to control and maintain equipment.
The constant pressure air supply control system increases the power frequency and frequency conversion switching function, and retains the original control and protection system. In addition, after adopting this scheme, the air compressor motor changes from static to rotating
The work can be started by the frequency converter, which realizes the soft start and avoids the mechanical impact of the start-up impact current and the start-up to the air compressor.
5. transformation programme principle:
The pressure closed-loop control system composed of frequency converter (variable frequency conversion can be done according to customer requirements), pressure transmitter (remote transmission pressure gauge), motor and spiral rotor automatically adjusts the motor speed to stabilize the air pressure in the air storage tank within the set range and carry out constant pressure control. The feedback pressure is compared with the set pressure, and the output of the frequency converter is controlled in real time, so as to adjust the speed and stabilize the air pressure in the air storage tank at the set pressure.
Ensure normal production. In the original pressure detection, we will add another pressure detection, the detected signal will be converted into a stable high-precision signal by the PID converter, and the frequency converter will reasonably adjust the main motor speed through the signal. Improve the performance of the entire system, while achieving good power saving purposes.
Aodi AD300 series inverter comes with protection systems such as overvoltage and undervoltage protection, overcurrent protection and overtemperature protection. Own heat dissipation and exhaust system; Ensure the stability of the machine. After the frequency converter is started, the pressure sensor transmits the data to the frequency converter, and feeds back the actual pressure value for the speed control of the motor. When the pressure difference is relatively large, the frequency converter will increase the motor speed to ensure that the pressure meets the output requirements; when the pressure difference is reduced, the frequency converter will reduce the motor speed to achieve the purpose of energy saving. When the pressure reaches the target requirement, the air compressor enters the empty state, the frequency converter enters the shutdown state according to the signal of the air compressor microcomputer, and the air pressure in the air tank is stable at the set pressure.
6. air compressor after the transformation of the benefits:
1) Energy saving
Inverter control compressor compared with the traditional control of the compressor, energy saving is the most practical significance, according to the air demand to supply the compressor operating conditions is the economic operating state.
2) Operating cost reduction
The operating cost of a traditional compressor consists of three items: initial purchase cost, maintenance cost and energy cost. Energy costs account for about 77% of compressor operating costs. By reducing the energy cost by 44.3, coupled with the impact on the equipment after the inverter is reduced, the maintenance and repair volume is also reduced, so the operating cost will be greatly reduced.
3) Improve pressure control accuracy
The variable frequency control system has precise pressure control capability. Match the air pressure output of the compressor to the amount of air required by the customer's air system. The output of the variable frequency control compressor changes with the change of the motor speed. Due to the improvement of the accuracy of the frequency conversion control motor speed, it can keep the system pressure change of the pipe network within the range of 3pisg, that is, within the range of 0.2bar, effectively improving the quality of the working condition.
4) Extend the service life of the compressor
The inverter starts the compressor from 0Hz, and its starting acceleration time can be adjusted, thereby reducing the impact on the electrical and mechanical components of the compressor during starting, enhancing the reliability of the system, and extending the service life of the compressor. In addition, the frequency conversion control can reduce the flow fluctuation when the unit starts, which will affect the power consumption of the power grid and other equipment, and the frequency converter can effectively reduce the peak value of the starting current to a minimum. Adjust the lower limit frequency to 40Hz, and then use an infrared thermometer to monitor the temperature rise of the air compressor motor and the oil temperature of the pipeline for a long time and strictly. The temperature rise of the motor is about 2-4 ℃, which is normal. The oil temperature basically does not change, and the exhaust temperature drops by 5 ℃. Therefore, 40Hz lower limit frequency operation is very safe for the work of the air compressor unit.
5) Reduce the noise of the air compressor
According to the working conditions of the compressor, after the transformation of frequency conversion speed regulation, the motor running speed is obviously slowed down, so the noise of the air compressor is effectively reduced. Field measurements show that the noise is reduced by about 3 to 7 decibels compared with the original system.
7. site conditions and parameter setting
An Electronics Co., Ltd. is a company specializing in precision plastic structural parts supporting product processing services, mainly to provide customers with: product structure design, mold design. The company's production consumption of gas is very large. Two Atlas 110KW air compressors are installed on the roof of the workshop. When only one air compressor is opened, the gas volume cannot meet the production demand, while when two air compressors are opened, the gas volume is too large, causing the motor to idle for a long time and wasting electric energy, and it is easy to cause unnecessary wear to the motor and shorten the service life of the motor. Therefore, users choose our current vector inverter for energy-saving transformation of Aodi AD300.
Specific parameters of air compressor:
The gas volume required for production is 0.76MPa, and a remote pressure sensor is installed on site, which can feed back the gas tank pressure to the frequency converter with 4-20mA current signal, so that the whole system can realize closed-loop control with frequency converter PID. When the pressure reaches the upper limit of the set pressure, the air compressor starts to unload, and the frequency converter allows the air compressor to run at the lower limit frequency;
When the pressure is lower than a certain value of the set frequency, the air compressor starts to load, and the frequency converter accelerates the air compressor to the upper limit frequency. This can not only meet the production needs quickly and efficiently, but also save energy to the greatest extent, and also extend the service life of the air compressor.
The corresponding parameters are set as follows:
Parameter Setting Value Interpretation
F0.02 = 1 (terminal control)
F0.03 = 7( PID control setting)
F0.13 = 25 (off-line frequency)
F0.19 = specific setting according to the field conditions (acceleration time)
F0.20 = specifically set according to the site conditions (deceleration time)
F1.08 = 1 (free parking)
F2.12 = 1 (reversal prohibited)
F6.01 = 1 (forward operation)
F8.00 = 0 (PID number given)
F8.01 = 1 (AI2 terminal)
F8.02 = Specific setting according to field conditions (given by analog PID number)
8. program advantages:
1. The line is mature, the stability is high, and the function meets the user's requirements;
2. Can choose power frequency/frequency conversion dual-purpose, flexible and convenient conversion, when the frequency conversion fails, it can still ensure the normal operation of the machine and ensure the production of the enterprise;
3, the use of two pressure detection, PID controller scientific conversion of pressure data, so that the air compressor system pressure more stable, high pressure accuracy;
4. The frequency converter we use is cost-effective, reliable in quality, and guaranteed for 18 months;
5, low cost, cost savings for the majority of enterprise users.
Application of Aodi Frequency Converter in Air Compressor
1. air compressor system overview:
The exhaust pressure adjustment device for the air compressor at the factory is mostly a closed intake pipe pressure regulator. Its working principle is that when the air pressure in the air storage tank (air bag) exceeds the set pressure, the compressor intake pipe The upper disc valve is automatically closed, and the compressor enters the idling unloading state. When the air pressure in the air storage tank is lower than the set pressure, the compressor intake pipe disc valve automatically opens, and the compressor enters the full load working state again. The displacement and pressure of the air compressor are not constant during operation. The air consumption often changes due to changes in working conditions. Therefore, the air compressor always repeats the full load-unloading mode when working. The working current at full load is close to the rated current of the motor, and the idling current at unloading is about 30-50% of the rated current of the motor. This part of the current is not useful work, but the idling loss of the machine at the rated speed. Although this mechanical adjustment device can also play a role in pressure adjustment, the pressure adjustment accuracy is low and the pressure fluctuation is large. The compressor always works at the rated speed, with high mechanical wear and high power consumption.
According to the theory of air compression, the shaft power, displacement and shaft speed of the compressor meet the following formula:
N=MrY*n/9553(KW)
Vd1=K*Vh1*n2(m3/min)
Where: N-shaft power of compressor (kw)
Mr-Average shaft torque of compressor input (N.m)
n-shaft speed of compressor (r/min)
Vd1 ---- Displacement at n2 speed ((m3/min)
K ------ Coefficients related to cylinder volume, pressure, temperature and leakage
Vh1 ---- Volume of primary cylinder (m3)
n2 ------ Adjusted compressor speed (r/min)
According to the above theoretical analysis, under the condition that the cylinder volume of the air compressor cannot be changed, the displacement can only be changed by adjusting the speed of the compressor; the air compressor is a constant torque load, and the compressor shaft power changes in direct proportion to the speed. When the total displacement of the compressor is greater than the total gas consumption, it is an effective way to achieve the economic operation of the compressor by reducing the speed of the compressor to adjust the air supply pressure. In the compressor can be used to change the pole motor, change the pulley transmission ratio, series pole speed control and other speed control methods, compared with other speed control methods, frequency conversion speed control has stepless speed regulation, easy to achieve automatic control, without changing the equipment structure and installation of small amount of characteristics.
The advantage of variable frequency speed regulation is that the pressure is given conveniently, and the set value can be adjusted at any time according to the change of gas consumption, which can realize the pressure closed-loop operation and realize the constant pressure supply of the compressor.
2. air compressor selection of the relevant requirements of the inverter:
The air compressor is a constant torque load, and a special frequency converter is selected. The main purpose of selecting the frequency converter for the compressor is to reasonably adjust the set value of the air supply pressure according to the required air volume to realize stable voltage and energy-saving operation. Constant torque frequency converter with the same capacity shall be selected according to the rated power of the matching motor. The frequency converter shall have built-in PID adjustment function and 4-20mA or 0-10V analog signal interface; The voltage variation rate of the place of use shall be within the allowable input voltage range of the frequency converter.
3. operation and effect:
The pressure sensor is installed on the gas storage tank, and the feedback output pressure signal is converted into an analog voltage signal or current signal (0-10V,4-20mA) that can be recognized by the frequency converter. If it is a desktop operation, the built-in PID function of the frequency converter can be directly used. If it is a multi-desktop operation, an external controller needs to be added to achieve the purpose of use. In the design and construction, it is best to keep the power frequency backup device. Once the inverter fails, the power frequency system can be used to ensure the continuation of production.
The working pressure is kept constant, and the automatic operation of the compressor is controlled by the inverter. After the equipment modification, the closed-loop control of the air supply pressure can be realized, the number of start and stop of the compressor is reduced, the labor intensity of the operator is reduced, the power consumption and mechanical wear are reduced, the service life of the machine is prolonged, and the economic benefit is improved.
4. air compressor benefits:
1. Energy Saving
Inverter control compressor compared with the traditional control of the compressor, energy saving is the most practical significance, according to the gas demand to supply the compressor operating conditions is the economic operation state.
2. Improve pressure control accuracy
The variable frequency control system has precise pressure control capability. Match the air pressure output of the compressor to the amount of air required by the customer's air system. The output air volume of the variable frequency control compressor changes with the change of the motor speed, which effectively improves the quality of the working condition.
3. Extend the service life of the compressor
The inverter starts the compressor from a low frequency, and its starting acceleration time can be adjusted, thereby reducing the impact on the electrical and mechanical components of the compressor during starting, enhancing the reliability of the system, and extending the service life of the compressor. In addition, the frequency conversion control can reduce the current fluctuation when the unit starts, which will affect the power consumption of the power grid and other equipment, and the frequency converter can effectively reduce the peak value of the starting current to a minimum.