Lifting industry
Release time:
2020-09-10
Tower cranes are developed for formwork technology in construction, and are suitable for lifting and transporting building materials and components in industrial and civil construction of reinforced concrete structures.
1. At present, the main speed regulation mode of domestic lifting mechanism:
Hoisting mechanism is the most important transmission mechanism of tower crane, at present, the traditional speed regulation mode requires heavy load low speed, light load high speed, wide speed range; hoisting mechanism speed control mode directly affects the performance of the whole machine. There are three principles for selecting the speed regulation mode of the lifting mechanism: first, it should be stable and small impact; secondly, it should be economical and reliable, in line with national conditions; third, it should be easy to maintain.
1.1 multi-speed motor pole-changing speed regulation
The competition of small and medium-sized tower cranes with the maximum lifting weight of 4 ropes less than or equal to 6T is fierce, and the cost control is strict. In China, the multi-speed motor is mainly used for pole change and speed regulation. The scheme is simple and widely used. 4/8/32 pole multi-speed motor is often used.
Single-speed wound rotor motor with eddy current brake and reducer 1.2 electromagnetic clutch shift
The speed control method has been used in China for decades, but now it is no longer used. It relies on electromagnetic clutch shifting to change the speed ratio of the reducer, and relies on the series resistance of a single-speed wound rotor motor with eddy current braking to obtain softer characteristics and slow positioning speed. Its advantage is that the operation is stable and the speed ratio can be designed to be large. It has many shortcomings. First, the electromagnetic clutch generally uses domestic machine tool products, which have short life and poor reliability; secondly, it cannot dynamically change the clutch gear in the air, otherwise it will decline, which is very dangerous; third, the cost of the reducer is high.
Multi-speed Wound Rotor Motor with Eddy Current Braking for 1.3 Ordinary Reducer
The idea of this method is to change the electromagnetic clutch shift of the previous method to a multi-speed motor to drive an ordinary single-speed ratio reducer. Compared with the disadvantage of large shift impact of multi-speed motors, multi-speed wound rotor motors with eddy current braking can obtain softer M-n characteristics with series resistance, braking and gear switching are more stable, and have a slow positioning speed. The power can be used more than squirrel cage motors. This speed control method has the advantages of simple structure, easy maintenance and high reliability. At present, the heat dissipation problem of eddy current brake wound rotor motor has been successfully solved, and the reliability of this speed regulation mode has been greatly improved.
At present, the domestic 8~12t lifting mechanism mostly adopts this speed regulation mode, but this kind of motor starting braking and shifting still has a large peak current and impact, the electrical control system is more complex, and the large tonnage lifting mechanism of more than 16t is generally not suitable for this speed regulation mode.
1.4 differential planetary reducer plus dual motors
The sun gear of the planetary reducer is driven by a motor, the planet carrier is driven by another motor through planetary reduction, and the inner ring gear of the outer track is fixed on the lifting drum. This is the construction of the differential planetary reducer. After the planetary system is determined as a suitable parameter, the drum speed depends on the speed and steering of the two motors, which is fast in the same direction and slow in the reverse direction. If it is a single-speed motor, each motor has three states of forward rotation, reverse rotation and stop to match another motor, so there are many speed gears. If you use a multi-speed motor, there will be more speed gears, which is the principle of differential speed regulation. The motor can use squirrel cage or frequency conversion combined with squirrel cage, smaller tonnage with squirrel cage, large tonnage with frequency conversion combined with squirrel cage. This way speed ratio is large, can fully meet the heavy load low speed, light load high speed requirements, and high reliability, especially suitable for large tonnage lifting mechanism.
However, the differential planetary reducer has a complex structure, and generally requires non-standard design and production. With dual motors, the cost is high and the control is complicated. Host manufacturers do not use much.
1.5 frequency conversion speed regulation
Variable frequency speed regulation is the most advanced way of AC speed regulation. With the gradual decline in the price of international frequency converters, the application of frequency conversion speed regulation technology is becoming more and more extensive. The domestic tower crane lifting mechanism has been applied for many years, the effect is good, but the use is not wide. Its advantage is that it can run for a long time at a slow speed, realize zero-speed braking, run smoothly and without impact, can extend the life of the structure and transmission parts, is of great benefit to the wire rope and life, and improves the safety of the tower crane.
However, its use area in the lifting mechanism is very narrow. First, imported frequency converters are still more expensive, while domestic frequency converters do not pass. Second, once there is a problem with the frequency converter, it cannot be repaired in general, and most of them can only be replaced. Due to the high cost of frequency conversion speed regulation, the application of small and medium-sized tonnage lifting mechanisms is generally less, while large tonnage is more. Variable speed regulation is used in large areas of small and medium tonnage, only waiting for the rise of domestic frequency converters.
2. Scheme of frequency converter in lifting mechanism of tower crane:
The application of frequency conversion technology in the lifting mechanism of tower cranes is mainly based on Japan's Yaskawa frequency converter, which is mainly used in large and medium-sized tower cranes. At the same time, the competition for small and medium-sized tower cranes with a maximum lifting weight of 4 ropes of 6T is fierce and the cost control is strict, so the application of frequency converter is very few. With the development of power electronics technology, domestic inverter technology is becoming more and more mature, and the price advantage is obvious. It has become possible to apply to small and medium tower cranes.
2.1 audette inverter profile:
The AD300 series inverter is a new generation of modular high-performance inverter introduced by Shenzhen Aodi Special Electric Technology Co., Ltd., which represents the future development direction of the inverter. Compared with the traditional inverter, it is not realized through multiple series of products to meet the different performance and functional requirements of customers (thus increasing the additional manufacturing, sales, use and maintenance costs), but on the basis of reasonable segmentation of customer needs, modular design is carried out, and a customized platform is created through the multi-module combination of single series of products. It is one of the few domestic inverters that really have magnetic flux vector technology.
This series of frequency converter adopts excellent speed-free vector control strategy to make it have fast dynamic response, advanced current limiting technology and hardware optimization design, which can ensure that the frequency converter does not trip under the condition of frequent load fluctuation. And has the following characteristics:
2.1.1 Reliability
Perfect reliability design scheme: such as redundancy design, derating design, etc., all components adopt industrial or military grade; professional production platform, so as to ensure the reliability of the whole machine.
2.1.2 Soft Start
Compared with the power frequency starting method, the use of frequency converter control can reduce the impact of mechanical part vibration and structural false, saving maintenance costs for users, stable operation.
2.1.3 High starting torque
Adopting high-performance flux vector control mode, the low frequency band provides stable high output torque.
2.2 Process Introduction
QTZ315 tower crane, a typical specification for small and medium-sized tower cranes, is widely used. The main technical indexes of magnification are: the maximum lifting weight is 3T, the lifting speed is 52/26/5.5 m/min, the 4/8/32 multi-pole motor of the lifting mechanism is 15/15/5.5KW, the speed ratio of the reducer I = 12.5, and the diameter of the drum is 300mm.
The most critical indicator for small and medium-sized tower cranes is the maximum lifting weight of 3T, the drum diameter of 300mm cannot be changed too much, and the speed requirements are relatively high. The selection of variable frequency speed regulation requires appropriate adjustment of relevant equipment and technical indicators.
2.3 parameter calculation
The crane frequency conversion speed regulation system is given by the master controller or potentiometer as the input, and is used in conjunction with frequency conversion frequency modulation speed regulation electronic control equipment, load measuring and controlling instrument, limit switch, brake, etc. to control the lifting mechanism of the crane and other AC frequency conversion asynchronous motors to start, brake, reversible operation and speed regulation.
Equipment selection parameters: 2 magnification of moving pulley, 18.5KW 4-pole asynchronous squirrel cage motor of lifting mechanism, speed ratio of reducer I = 31.5; Drum diameter is 300mm, I .e. I = 31.5,R = D/2=150mm = 0.15m,Nn = 1450 r/min, Pn = 18.5KW.
2.3.1 Calculation of maximum lifting weight:
PN = 2 *π*nn*tn/ 60*1000: TN = pn* 1000*60/2 *π* NN = 18.5*1000*60/2π * 1450 = 121.9nm
The theoretical lifting weight is: F = 2 * Tn * I */R * 10000=2*121.9*31.5/0.15*10000=5.1198T
Considering that the transmission efficiency is 0.64, the maximum lifting weight is: Fmax = 0.64 * F = 0.64*5.1198=3.28T
Compared with the required maximum lifting weight, it has a safety factor of 1.1 times, which basically meets the requirements.
2.3.2 Calculation of maximum lifting speed
Vmax=p*D*Nn/2*I=p*0.3*1450/2*31.5=21.7 m/min
According to the above formula, the maximum lifting speed of the motor is reduced a lot in the frequency conversion mode, mainly considering cost saving and competitiveness in the market, and the relevant hardware cost is estimated to be optimized in the design. By shortening the start-up and positioning time, running the empty hook above 50HZ and other coordination methods, the speed is not obviously felt to slow down in practice.
2.4 performance characteristics
The advanced modern AC frequency conversion speed regulation technology is adopted to carry out technical transformation on the electric drive system of tower crane, so that the crane can operate smoothly, improve the operation efficiency, improve the overload operation, eliminate the braking impact, reduce the electrical maintenance, reduce the power consumption, improve the power deficiency factor and so on. At the same time, it also has overcurrent, overvoltage, undervoltage and input phase loss protection, as well as inverter overtemperature, overload, overspeed, brake unit overheating, I/O fault protection, motor fault protection, etc. The frequency conversion speed regulation method has the following remarkable characteristics:
(1) The speed range is wide, which can realize the operation with precise control and positioning requirements;
(2) The function of soft start and soft stop reduces the impact of mechanical transmission, can significantly improve the bearing performance of the steel structure, and extend the service life of the crane;
(3) high integration of components and high reliability of low-voltage electrical appliances, effectively solve the original electrical system wiring complex problems, not only reduce the probability of system failure, but also easy to maintain;
(4) When the motor is at zero speed, it can output full torque, even if the brake is loose or fails, there will be no heavy objects to slide down, ensuring the safety and reliability of the system;
(5) With fast dynamic response, there will be no slip hook and truly realize the "zero speed cross" function;
(6) The special load weight measuring and controlling instrument is equipped with corresponding software, and the lifting speed can be self-switched with the change of load weight, so as to realize the operation requirements of "light load fast, heavy load slow;
(7) The frequency converter used in the system has an automatic energy-saving operation mode, which can greatly improve the power factor of the system and the working efficiency of the whole machine, and the energy-saving effect is remarkable, and the average power saving rate can reach more than 20%;
3. Concluding remarks:
So far, the design of the tower crane without speed vector frequency conversion speed regulation has been tested for three months, the whole equipment is running well, and 4 sets of orders have been accepted.
At present, the vast majority of tower cranes use step speed regulation, stepless speed regulation is the direction of development, but it is still limited by cost and other aspects. The author has done calculations, using the above-mentioned similar method of not increasing the frequency converter selection, appropriate sacrifice of speed, the cost of variable frequency stepless speed regulation and with eddy current braking multi-speed wound rotor motor pole change speed difference is not big, but the performance has been greatly improved, visible significance.
Previous
Previous
Latest information
The role of the inverter in the four aspects of industry
The energy saving level of frequency converter is mainly reflected in the application of fan and centrifugal pump. After selecting the wind turbine and pump load, the energy saving rate is 20%-60% due to the ratio of the specific cost of the wind turbine and the pump load and the three-square speed ratio.
2020-07-29
What are the differences between frequency converter and soft starter
The frequency converter is a power output control system that uses the principle of inverter and electronic information technology to control the communication motor according to the frequency change of the switching power supply.
2020-07-29
11KW-15KW plastic shell inverter research and development completed, small batch trial production!
11KW-15KW plastic shell inverter research and development completed, small batch trial production!
2020-07-29